Sceptre PB-2457A Adapter - Over-voltage,over-load and short-circuit protection, Power Factor Correction (PFC), EN55022, FCC conducted and radiated emission Simple Type: Adapter

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 100 ~ 240Vac Universal Input
  • Convection cooled
  • EN55022, FCC conducted and radiated emission
  • Impact resistant polycarbonate enclosure
  • LED AC power indicator
  • Over-voltage,over-load and short-circuit protection
  • Power Factor Correction (PFC)
  • UL, CE approvals
  • Up to 137W continuous external power supply

Specifications

    General
  • BURN-IN: The power supply shall under go a minimum of 4hours Burn-In test under full
  • Cooling: The power supply will operate with convection cooling. Blocking of vents must not cause damage to the power supply.
  • EFFICIENCY: Higher than 87%, @ 115/230Vac 60/50Hz input and full load output. Typical is 92%
  • INPUT CURRENT: 2.0Amax
  • INPUT FREQUENCY RANGE: 50Hz to 60Hz.
  • INPUT RATED VOLTAGE: 100VAC to 240VAC
  • INPUT VOLTAGE RANGE: 90VAC to 264VAC.
  • INRUSH CURRENT: 90Amax. at 264VAC input for a cold start at 25oC
  • MTBF: When the power supply is operating within the limits of this specification the MTBF shall be at least 50,000hours at 25oC (MIL-STD-217F).
  • NON – OPERATING: The power supply shall be capable of withstanding the following environmental conditions for extended periods of time, without sustaining electrical or mechanical damage and subsequent operational deficiencies.
  • OPERATING: The power supply shall be capable of operating continuously in any mode without
  • OVER - CURRENT PROTECTION: The adaptor must have a current limiting function on the output voltage. In overload mode, the output must drop to a low voltage.
  • OVER - VOLTAGE PROTECTION: Over-voltage protection shall be included in the adaptor circuit. A single component failure must not cause an over voltage condition.
  • PFC (Power Factor Correction): Provisions for adding harmonic reduction per EN61000-3-2 must be present. Min 0.9 at output full load, 100~240 VAC input.
  • Relative Humidity: 10% ~ 90%
  • SHORT - CIRCUIT PROTECTION: The adaptor must withstand a continuous short circuit on the output without damage.
  • STANDBY POWER: Equal or less than 0.3W
  • Storage Temperature: -30oC ~ 70oC
  • Vibration: 1.0mm, 10–25Hz, 15 minutes per cycle for each axis (X, Y, Z)

 

Applications

  • None Available

Aliases