Sceptre PB-2457A Adapter - Over-voltage,over-load and short-circuit protection, Power Factor Correction (PFC), EN55022, FCC conducted and radiated emission Simple Type: Adapter
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- 100 ~ 240Vac Universal Input
- Convection cooled
- EN55022, FCC conducted and radiated emission
- Impact resistant polycarbonate enclosure
- LED AC power indicator
- Over-voltage,over-load and short-circuit protection
- Power Factor Correction (PFC)
- UL, CE approvals
- Up to 137W continuous external power supply
Specifications
- BURN-IN: The power supply shall under go a minimum of 4hours Burn-In test under full
- Cooling: The power supply will operate with convection cooling. Blocking of vents must not cause damage to the power supply.
- EFFICIENCY: Higher than 87%, @ 115/230Vac 60/50Hz input and full load output. Typical is 92%
- INPUT CURRENT: 2.0Amax
- INPUT FREQUENCY RANGE: 50Hz to 60Hz.
- INPUT RATED VOLTAGE: 100VAC to 240VAC
- INPUT VOLTAGE RANGE: 90VAC to 264VAC.
- INRUSH CURRENT: 90Amax. at 264VAC input for a cold start at 25oC
- MTBF: When the power supply is operating within the limits of this specification the MTBF shall be at least 50,000hours at 25oC (MIL-STD-217F).
- NON – OPERATING: The power supply shall be capable of withstanding the following environmental conditions for extended periods of time, without sustaining electrical or mechanical damage and subsequent operational deficiencies.
- OPERATING: The power supply shall be capable of operating continuously in any mode without
- OVER - CURRENT PROTECTION: The adaptor must have a current limiting function on the output voltage. In overload mode, the output must drop to a low voltage.
- OVER - VOLTAGE PROTECTION: Over-voltage protection shall be included in the adaptor circuit. A single component failure must not cause an over voltage condition.
- PFC (Power Factor Correction): Provisions for adding harmonic reduction per EN61000-3-2 must be present. Min 0.9 at output full load, 100~240 VAC input.
- Relative Humidity: 10% ~ 90%
- SHORT - CIRCUIT PROTECTION: The adaptor must withstand a continuous short circuit on the output without damage.
- STANDBY POWER: Equal or less than 0.3W
- Storage Temperature: -30oC ~ 70oC
- Vibration: 1.0mm, 10–25Hz, 15 minutes per cycle for each axis (X, Y, Z)
Applications
- None Available